  "version": 2,
  "polls": [
    {
      "name": "Pump status 00201-00226 (wire 200)",
      "fc": 3,
      "addr": 200,
      "qty": 26,
      "slaveId": 1,
      "interval": 2000,
      "disabled": false,
      "chart": {
        "paused": false,
        "crosshair": false,
        "cursorX": null,
        "dragging": false,
        "layout": null,
        "data": []
      },
      "log": {
        "active": false,
        "buffer": [],
        "startTime": null,
        "count": 0
      },
      "chartReg": 200,
      "chartName": "Pump status 00201-00226 (wire 200) [200]",
      "logFile": "log_Pump_status_00201_00226_wire_200_.txt"
    },
    {
      "name": "Pump data 00301-00336 (wire 300)",
      "fc": 3,
      "addr": 300,
      "qty": 36,
      "slaveId": 1,
      "interval": 2000,
      "disabled": false,
      "chart": {
        "paused": false,
        "crosshair": false,
        "cursorX": null,
        "dragging": false,
        "layout": null,
        "data": []
      },
      "log": {
        "active": false,
        "buffer": [],
        "startTime": null,
        "count": 0
      },
      "chartReg": 300,
      "chartName": "Pump data 00301-00336 (wire 300) [300]",
      "logFile": "log_Pump_data_00301_00336_wire_300_.txt"
    }
  ],
  "activePoll": 0,
  "condColors": {},
  "scaling": {},
  "valueNames": {},
  "chartSeries": [],
  "slaveBlocks": [],
  "dashTheme": "modern",
  "dashFx": true,
  "dashBgColor": "#0d1117",
  "dashPages": [
    {
      "id": 1,
      "name": "MAGNA3",
      "elements": [
        {
          "id": 1,
          "value": 0,
          "type": "statictext",
          "x": 20,
          "y": 10,
          "w": 840,
          "h": 30,
          "text": "Grundfos MAGNA3  ·  CIM 200, Modbus RTU 19200 8E1  ·  register X = wire X - 1",
          "fontSize": 20,
          "bold": true,
          "color": "#e6eef8"
        },
        {
          "id": 2,
          "value": 0,
          "type": "pump",
          "x": 20,
          "y": 50,
          "w": 300,
          "h": 220,
          "label": "P-1 MAGNA3 heating circuit",
          "threshold": 1,
          "color": "#3b82f6",
          "view": "values",
          "pts": {
            "fault": {
              "src": "tag",
              "tagName": "Alarm"
            },
            "flow": {
              "src": "tag",
              "tagName": "Flow_m3h"
            },
            "pout": {
              "src": "tag",
              "tagName": "Head_bar"
            },
            "speed": {
              "src": "tag",
              "tagName": "Rel_Perf"
            }
          },
          "sourceType": "tag",
          "tagName": "Running"
        },
        {
          "id": 3,
          "value": 0,
          "type": "multistate",
          "x": 340,
          "y": 50,
          "w": 250,
          "h": 66,
          "label": "Control mode 00203",
          "states": "128=AUTOADAPT:#3fd28a,129=FLOWADAPT:#3fd28a,6=Proportional pressure:#58a6ff,5=Const. diff. pressure:#58a6ff,0=Const. speed:#f0c040,7=Const. flow:#58a6ff",
          "sourceType": "tag",
          "tagName": "Control_Mode"
        },
        {
          "id": 4,
          "value": 0,
          "type": "multistate",
          "x": 600,
          "y": 50,
          "w": 260,
          "h": 66,
          "label": "Control 00201 bit 8",
          "states": "0=Local:#9fb3cc,1=Remote (bus):#3fd28a",
          "sourceType": "tag",
          "tagName": "Remote"
        },
        {
          "id": 5,
          "value": 0,
          "type": "text",
          "x": 340,
          "y": 126,
          "w": 140,
          "h": 66,
          "label": "Speed 00304",
          "unit": "rpm",
          "decimals": 0,
          "fontSize": 24,
          "color": "#00d4aa",
          "sourceType": "tag",
          "tagName": "Speed_rpm"
        },
        {
          "id": 6,
          "value": 0,
          "type": "text",
          "x": 490,
          "y": 126,
          "w": 140,
          "h": 66,
          "label": "Power 00312",
          "unit": "W",
          "decimals": 0,
          "fontSize": 24,
          "color": "#00d4aa",
          "sourceType": "tag",
          "tagName": "Power_W"
        },
        {
          "id": 7,
          "value": 0,
          "type": "text",
          "x": 640,
          "y": 126,
          "w": 220,
          "h": 66,
          "label": "Liquid 00322",
          "unit": "°C",
          "decimals": 1,
          "fontSize": 24,
          "color": "#00d4aa",
          "sourceType": "tag",
          "tagName": "Liquid_C"
        },
        {
          "id": 8,
          "value": 0,
          "type": "text",
          "x": 340,
          "y": 202,
          "w": 140,
          "h": 66,
          "label": "Setpoint 00308",
          "unit": "%",
          "decimals": 1,
          "fontSize": 24,
          "color": "#00d4aa",
          "sourceType": "tag",
          "tagName": "Setpoint_pct"
        },
        {
          "id": 9,
          "value": 0,
          "type": "text",
          "x": 490,
          "y": 202,
          "w": 140,
          "h": 66,
          "label": "Specific energy",
          "unit": "Wh/m³",
          "decimals": 0,
          "fontSize": 24,
          "color": "#00d4aa",
          "sourceType": "tag",
          "tagName": "Spec_Energy"
        },
        {
          "id": 10,
          "value": 0,
          "type": "text",
          "x": 640,
          "y": 202,
          "w": 220,
          "h": 66,
          "label": "Energy 00332",
          "unit": "kWh",
          "decimals": 0,
          "fontSize": 24,
          "color": "#00d4aa",
          "sourceType": "tag",
          "tagName": "Energy_kWh"
        },
        {
          "id": 11,
          "value": 0,
          "type": "multistate",
          "x": 340,
          "y": 278,
          "w": 250,
          "h": 56,
          "label": "Alarm code 00205",
          "states": "0=No alarm:#3fd28a,51=Blocked motor/pump:#f85149,57=Dry running:#f85149,64=Overtemperature:#f85149,88=Sensor fault:#f85149,159=CIM lost the pump:#f85149",
          "sourceType": "tag",
          "tagName": "Alarm_Code"
        },
        {
          "id": 12,
          "value": 0,
          "type": "text",
          "x": 600,
          "y": 278,
          "w": 125,
          "h": 66,
          "label": "Hours 00327",
          "unit": "h",
          "decimals": 0,
          "fontSize": 24,
          "color": "#00d4aa",
          "sourceType": "tag",
          "tagName": "Hours"
        },
        {
          "id": 13,
          "value": 0,
          "type": "text",
          "x": 735,
          "y": 278,
          "w": 125,
          "h": 66,
          "label": "Starts 00334",
          "unit": "",
          "decimals": 0,
          "fontSize": 24,
          "color": "#00d4aa",
          "sourceType": "tag",
          "tagName": "Starts"
        },
        {
          "id": 14,
          "value": 0,
          "type": "multitend",
          "x": 20,
          "y": 345,
          "w": 840,
          "h": 195,
          "label": "Flow (m³/h) and head (bar x 10)",
          "maxPoints": 1200,
          "decimals": 2,
          "sampleMs": 2000,
          "yMin": 0,
          "yMax": 15,
          "items": [
            {
              "name": "Flow 00302",
              "sourceType": "tag",
              "tagName": "Flow_m3h",
              "color": "#58a6ff",
              "value": 0
            },
            {
              "name": "Head 00301 x 10",
              "sourceType": "tag",
              "tagName": "Head_x10",
              "color": "#f0c040",
              "value": 0
            }
          ]
        }
      ]
    }
  ],
  "tags": [
    {
      "name": "Status",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 200,
      "dataType": "uint16",
      "wordOrder": "big",
      "description": "status bits: 6 rotation, 8 remote, 9 on, 10 alarm, 11 warning (register 00201, wire 200)",
      "scale": 1,
      "offset": 0
    },
    {
      "name": "Feedback_pct",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 201,
      "dataType": "uint16",
      "wordOrder": "big",
      "description": "process feedback % of sensor range (register 00202, wire 201)",
      "scale": 0.01,
      "offset": 0
    },
    {
      "name": "Control_Mode",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 202,
      "dataType": "uint16",
      "wordOrder": "big",
      "description": "control mode: 128 AUTOADAPT, 129 FLOWADAPT, 6 proportional pressure ... (register 00203, wire 202)",
      "scale": 1,
      "offset": 0
    },
    {
      "name": "Operation_Mode",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 203,
      "dataType": "uint16",
      "wordOrder": "big",
      "description": "operation mode: 0 auto, 4 min, 6 max, 7 user curve, 8 stop, 9 hand (register 00204, wire 203)",
      "scale": 1,
      "offset": 0
    },
    {
      "name": "Alarm_Code",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 204,
      "dataType": "uint16",
      "wordOrder": "big",
      "description": "alarm code (0 = none) (register 00205, wire 204)",
      "scale": 1,
      "offset": 0
    },
    {
      "name": "Warning_Code",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 205,
      "dataType": "uint16",
      "wordOrder": "big",
      "description": "warning code (0 = none) (register 00206, wire 205)",
      "scale": 1,
      "offset": 0
    },
    {
      "name": "Head_bar",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 300,
      "dataType": "uint16",
      "wordOrder": "big",
      "description": "head bar (register 00301, wire 300)",
      "scale": 0.001,
      "offset": 0
    },
    {
      "name": "Flow_m3h",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 301,
      "dataType": "uint16",
      "wordOrder": "big",
      "description": "volume flow m3/h, estimated (register 00302, wire 301)",
      "scale": 0.1,
      "offset": 0
    },
    {
      "name": "Rel_Perf",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 302,
      "dataType": "uint16",
      "wordOrder": "big",
      "description": "relative performance % (register 00303, wire 302)",
      "scale": 0.01,
      "offset": 0
    },
    {
      "name": "Speed_rpm",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 303,
      "dataType": "uint16",
      "wordOrder": "big",
      "description": "speed rpm (register 00304, wire 303)",
      "scale": 1,
      "offset": 0
    },
    {
      "name": "Setpoint_pct",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 307,
      "dataType": "uint16",
      "wordOrder": "big",
      "description": "actual setpoint % of the setpoint range (register 00308, wire 307)",
      "scale": 0.01,
      "offset": 0
    },
    {
      "name": "Power_W",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 311,
      "dataType": "uint32",
      "wordOrder": "big",
      "description": "power W (HI then LO) (register 00312, wire 311)",
      "scale": 1,
      "offset": 0
    },
    {
      "name": "Liquid_K",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 321,
      "dataType": "uint16",
      "wordOrder": "big",
      "description": "pumped liquid temperature, 0.01 K (register 00322, wire 321)",
      "scale": 0.01,
      "offset": 0
    },
    {
      "name": "Spec_Energy",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 325,
      "dataType": "uint16",
      "wordOrder": "big",
      "description": "specific energy Wh/m3 (register 00326, wire 325)",
      "scale": 1,
      "offset": 0
    },
    {
      "name": "Hours",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 326,
      "dataType": "uint32",
      "wordOrder": "big",
      "description": "operating hours (register 00327, wire 326)",
      "scale": 1,
      "offset": 0
    },
    {
      "name": "Energy_kWh",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 331,
      "dataType": "uint32",
      "wordOrder": "big",
      "description": "energy kWh (register 00332, wire 331)",
      "scale": 1,
      "offset": 0
    },
    {
      "name": "Starts",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 333,
      "dataType": "uint32",
      "wordOrder": "big",
      "description": "number of starts (register 00334, wire 333)",
      "scale": 1,
      "offset": 0
    },
    {
      "name": "Running",
      "type": "internal",
      "slaveId": 0,
      "regType": "holdingRegisters",
      "address": 0,
      "dataType": "float32",
      "wordOrder": "big",
      "value": 0,
      "description": "1 while the pump rotates (status bit 6)"
    },
    {
      "name": "Remote",
      "type": "internal",
      "slaveId": 0,
      "regType": "holdingRegisters",
      "address": 0,
      "dataType": "float32",
      "wordOrder": "big",
      "value": 0,
      "description": "1 when the bus controls the pump (status bit 8)"
    },
    {
      "name": "Alarm",
      "type": "internal",
      "slaveId": 0,
      "regType": "holdingRegisters",
      "address": 0,
      "dataType": "float32",
      "wordOrder": "big",
      "value": 0,
      "description": "1 when the pump has an alarm (status bit 10)"
    },
    {
      "name": "Liquid_C",
      "type": "internal",
      "slaveId": 0,
      "regType": "holdingRegisters",
      "address": 0,
      "dataType": "float32",
      "wordOrder": "big",
      "value": 0,
      "description": "pumped liquid °C, from 0.01 K as absolute kelvin"
    },
    {
      "name": "Head_x10",
      "type": "register",
      "slaveId": 1,
      "regType": "holdingRegisters",
      "address": 300,
      "dataType": "uint16",
      "wordOrder": "big",
      "description": "head in bar x 10, for the trend (register 00301, wire 300)",
      "scale": 0.01,
      "offset": 0
    }
  ],
  "script": "(* Grundfos status word 00201: bit 6 rotation, bit 8 remote access, bit 10 alarm *)\nRunning := ((Status - (Status MOD 64)) / 64) MOD 2;\nRemote := ((Status - (Status MOD 256)) / 256) MOD 2;\nAlarm := ((Status - (Status MOD 1024)) / 1024) MOD 2;\n(* 0.01 K, read as absolute kelvin (Grundfos does not state an offset) *)\nLiquid_C := Liquid_K - 273.15;\n",
  "scriptInterval": "1000",
  "historianLogging": {
    "registers": [],
    "tags": []
  },
  "saved": "2026-11-14T12:00:00.000Z"
}