Modbus Device Guides and How-tos

Every guide on this site in one place: 42 pages on reading real devices over Modbus — inverters, energy meters, drives, PLCs — and on the protocol details that trip people up. Each device guide has its register map from the vendor's own documents, the traps an integrator meets, and most come with a free ModbusManager workspace you can open and point at your device.

Solar & inverters

Huawei SmartLoggerfree workspaceSmartLogger3000 and 3000A register map: inverter address formula, key SUN2000 registers and status values, plus a free 24-inverter workspace. Huawei SUN2000free workspaceSUN2000 inverter Modbus registers: active power 32080, yield 32114, status 32089, meter 37113. Enable Modbus TCP on the SDongle, unit ID, port, free workspace. SUN2000 → Home Assistantfree workspaceGet a Huawei SUN2000 and DTSU666-H meter into Home Assistant locally: one Modbus TCP connection, MQTT discovery, Energy dashboard ready. Free workspace. Sungrow Invertersfree workspaceSungrow SG and SH inverter Modbus registers: addresses minus one, FC04 vs FC03, low-word-first 32-bit values, work states, WiNet-S setup, free workspace. SunSpec: SMA, Fronius, SolarEdgefree workspaceSunSpec Modbus explained for SMA, Fronius and SolarEdge: SunS marker at 40000, model 103 registers, scale factors, unit IDs and ports per brand, free workspace. Victron Cerbo GXfree workspaceVictron GX Modbus TCP: enable the server, Unit-ID 100 for system data, 227 for the MultiPlus, registers 840-850, scale factors, 0x0A/0x0B. Free workspace. GoodWe ET Hybridfree workspaceGoodWe ET / EH hybrid inverter Modbus: factory address 247, 9600 8N1, FC03, PV at 35103, battery 35180, SOC 37007, work and battery mode. Free workspace. Deye, Sunsynk & Growattfree workspaceDeye, Sunsynk and Growatt hybrid inverter Modbus registers: battery SOC, grid and load power, signs, FC03 vs FC04, word order, RS485 settings, free workspace. Lufft WS weather sensorsfree workspaceLufft WS200-WS600 weather sensor Modbus RTU: switch from UMB with the Config Tool, 19200 8E1, Reg. Addr. vs Reg. No., 65535 = not fitted. Free workspace.

EV charging

Alfen Eve EV chargerfree workspaceAlfen Eve (NG9xx) Modbus TCP: licence, unit ID 200 station / 1 socket, FLOAT32 meter, Mode 3 state string, max current every 60 s. Free workspace.

Energy meters

Schneider PM5000free workspacePowerLogic PM5000 series register list — PM5300, PM5320, PM5350, PM5500 — over Modbus RTU or TCP with FLOAT32 decoding, plus a free workspace file. Schneider PM3250free workspaceSchneider PM3200 series on Modbus: only PM3250/PM3255, register = address + 1, FC03/FC16 only, PF -2..+2, Int64 vs Float32 energy. Free workspace. Eastron SDM630free workspaceSDM630 and SDM630MCT register list with FLOAT32 decoding and FC04 addresses, plus a free ready-made workspace to start polling in minutes. Eastron SDM120free workspaceSDM120-Modbus register map with FLOAT32 decoding, factory defaults (2400 baud, ID 1) and RS-485 wiring, plus a free ready-made workspace for Windows. Eastron SDM230 / SDM72free workspaceEastron SDM230 and SDM72 Modbus: FC04 input registers, even register count, 30 values max, SDM72D-M nine registers vs SDM72DM-V2. Free workspace. Carlo Gavazzi EM340 / EM24free workspaceCarlo Gavazzi EM340 / EM24 Modbus: physical = Modicom - 300001, INT32 low word first, V x10, A x1000, FC03 = FC04, EM24 E1 192.168.1.10. Free workspace. Janitza UMG 96-PAfree workspaceJanitza UMG 96-PA Modbus: the 19000 Float32 block, W and Wh units, little-endian at address + 32768, baud rate Auto, address 1-250. Free workspace. Socomec DIRIS A-40free workspaceSocomec DIRIS A-40 Modbus table: legacy block 50512 (power in 10 W) vs 18476 (W), frequency Hz/100 vs mHz, THD and harmonics. Free workspace. WattNodeWhy a new WattNode reads voltage correctly but power wrong, which register fixes it, and how to commission the meter over RS-485 in minutes.

Heat pumps & HVAC

NIBE S-series heat pumpsfree workspaceNIBE S1155/S1255 Modbus TCP: switch it on in menu 7.5.9, port 502, FC04 measurements, FC03 settings, degree minutes, 20-register limit. Free workspace. CoolMasterNet VRFfree workspaceCoolMasterNet Modbus for Daikin, Mitsubishi, LG VRF: Virtual Addresses, unit ID 80, the 16-address block per indoor unit, fault 65535. Free workspace. Grundfos MAGNA3 (CIM)free workspaceGrundfos MAGNA3 Modbus via CIM 200 (RTU 19200 8E1) or CIM 500 (TCP): register X = wire X-1, remote access bit, setpoint in %. Free workspace. Carel pCO (chiller / AHU)free workspaceCarel pCO Modbus: D[n] = coil n, A[n] = register n x 10, I[n] = register 128 + n, the threshold, n or n+1, and a chiller example. Free workspace.

Drives & EC fans

ABB ACS580free workspaceControl word, status word, speed reference and actual value registers for ACS580 over Modbus RTU, plus a free ready-made workspace for Windows. ABB ACS880free workspaceEmbedded fieldbus or FSCA-01 adapter, ABB Drives profile control word, status and reference registers, plus a free ready-made workspace for Windows. ABB ACH580free workspaceABB ACH580 Modbus RTU: holding registers, group 58 setup, control word 0x047F, 20000 = 46.02 scaling, DI4 start interlock, Act2 = 0. Free workspace. Danfoss FC 102 / FC 302free workspaceDanfoss VLT FC 102 / FC 302 on Modbus RTU: 8-30 setup, register = 10 x parameter, conversion index, CTW 50000, STW 50200, 0x047C. Free workspace. Schneider ATV320 / ATV630free workspaceAltivar ATV320 / ATV630 Modbus RTU: address OFF from the factory, 6001-6005 settings, scanner 12741 ETA / RFRD, CMD 0x000F, no minus one. Free workspace. Siemens SINAMICS G120free workspaceSINAMICS G120 CU240B-2 / CU240E-2 on Modbus RTU: p2030 = 2, address switch, STW1 40100, ZSW1 40110, diagnostics 40340, 0x047F. Free workspace. PowerFlex 525Why PowerFlex 525 Modbus reads land one register off, which function codes the drive answers, and how to verify it on a live drive with a free tool. DURApulse GS20How any GS20 parameter number converts into a Modbus register, where the two control words live, and how to verify both on a real drive. Yaskawa V1000V1000 and GA500 MEMOBUS register addresses for run command, frequency reference and output monitoring, plus H5 parameters and why FC06 is rejected. ebm-papst EC Fanfree workspaceMonitor and control a bank of ebm-papst EC fans on one live dashboard. Free 16-fan demo workspace, runs on the built-in simulator or real fans. VFD Speed RegistersWhich Modbus holding register sets a VFD frequency setpoint from a PLC: the speed reference and control word addresses for ABB ACS580/ACS880, Yaskawa V1000, PowerFlex 525 and DURApulse GS20 — and how to get the scaling right.

Siemens PLCs

Siemens S7-1200 HMITurn ModbusManager Pro into a live HMI for your S7-1200 over Modbus TCP. Free demo project with SCL code and workspace you can run on real hardware. Siemens S7 PUT/GETfree workspaceRead and write Siemens S7-1200/1500 DBs, merkers and I/O from a PC over PUT/GET: TIA settings, address format, HMI, logging and an S7-Modbus gateway.

Controllers

Omron E5CC temperature controllerfree workspaceOmron E5CC Modbus RTU: switch PSEL from CompoWay/F, 4-byte map at 0x0000 vs 2-byte at 0x2000, Decimal Point Monitor, RUN/STOP bit. Free workspace. Danfoss AK-CC 350 case controllerfree workspaceDanfoss AK-CC 350 case controller Modbus: PNU minus one, temperatures as one register x 0.1, r00 cutout, EKC state, alarm bits 20000+. Free workspace. Deep Sea DSE7320 generatorfree workspaceDSE7320 MKII Modbus RTU via GenComm: address = page x 256 + offset, 8N1, sentinels like 0xFFFF, alarm flags, start/stop keys. Free workspace.

Modbus how-to

Modbus RTU over TCP vs Modbus TCP: Which Your Converter NeedsRTU over TCP sends the serial frame with its CRC; Modbus TCP adds an MBAP header. How to tell which your serial device server needs, and how to test it. Modbus TCP Security (TLS, Port 802): Certificates and TestingModbus/TCP Security wraps Modbus in TLS on port 802 with X.509 certificates on both sides. What you need, test certificates with OpenSSL, how to connect. Modbus to MQTT Gateway for Windows (RTU & TCP, Home Assistant)free workspacePublish Modbus RTU and TCP registers to MQTT: one retained topic per value, Home Assistant discovery, writes over /set. No code. Free SDM630 workspace.
Your device is not here? Send the PDF of its Modbus register list to the register map service and get a ready workspace back, or read it yourself with the Modbus scanner.